0

Out of 0 Ratings

Owner's of the Acnodes Car Video System PMH 8064 gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 25
 
14628 Central Blvd,
Chino, CA91710
tel:909.597.7588, fax:909.597.1939
© Copyright 2011 Acnodes, Inc.
All rights reserved. Product description and product specifications
are subject to change without notice. For latest product information,
please visit Acnodes’ web site at www.acnodes.com.
PMH 8064
6.5” open frame monitor
1000-nits high brightness LCD
2. 4 points calibration
It needs calibration before the touchscreen can work accurately. Whenever the user feel the accuracy
lost, user can do calibration again to get a more accuracy touch function.
Pressing this button, a new window will be popped-up at the location when the touchscreen was
mapped to area for this touch system to guide the user do 4 points calibration.
User should follows the guide to touch and hold the blinking X symbol in the calibration window until it
does not blink to make sure that the utility can gather enough data for computation. In addition, a time
line bar is shown in the bottom of the window to indicate time elapsed. If the touchscreen was not
touched before the time line bar going to right end, the calibration task will be terminated automati-
cally.
3. Clear and Calibration
Press this button to erase the 25 points calibration/linearization parameters and force user to do 4
points cali- bration again. After 25 points calibration data was clear, the 4 points calibration data will
be invalid. It needs to do 4 points calibration.
4. Linearization
Linearization ( 25 or 9 points calibration ) function is used to compensate the touchscreen linearity.
After lin- earization completed, the linearity of the touchscreen will be shown in the Linearity curve
window.